This is Photoshop’s version of Lorem Ipsn gravida nibh vel velit auctor aliquet.Aenean sollicitudin, lorem quis bibendum auci. Proin gravida nibh vel veliau ctor aliquenean.

FOLLOW ME ON INSTAGRAM

+01145928421
mymail@gmail.com

uniTemp – Temperature Controller

Add to Wishlist Remove from Wishlist

Easy-to-use temperature controller for electrophysiology

  • Set temperature & GO
  • Preset control parameters matched to heater
  • Additional input for external sensor
  • Designed for use with ALA’s perfusion and stage heaters

Technical Data

Digital displays: 3 1/2 digits, XX.X °C
Setpoint control: 3-turn potentiometer
range: 18°C to to 50.0 °C
Heater output: 12 V / 2 A, continuous DC
short circuit protected,
Control: PI (proportional-integral) controller,
factory-set parameters;
accuracy typically ±0.2 °C
Sensor input: for semiconductor 2252 Ohm at 25 °C,
accuracy typically 0.1 °C at 25 °C,
with electronic protection
Measuring accuracy: 0.1 °C at 25 °C
Power requirements: 115 V / 230 V AC, 60/50 Hz,
fuse 0.4 A / 0.2 A slow
Dimensions: desktop cabinet, 165 x 265 x 95 mm

Ordering

Part no. Description
UNITEMP uniTemp Temperature Controller
UNITEMP-TS100 Temperature sensor for uniTemp systems

Downloads

Manual uniTemp manual
Brochures uniTemp

Temperature Controllers

ABOUT

The uniTemp temperature controllers are straightforward in use: just set the desired temperature with the rotary knob and connect the heater. All control parameters (gain, speed, etc.) are factory-set to match the heating device that is intended to be used with the system. Among these are perfusion heaters, heated microscope stages, animal heating pads and objectve heaters. An additional external sensor can be used optionally to check the actual temperature.
npi’s temperature controllers are designed for use in sensitive electrophysiological recording setups. The analog control circuits ensure that no switching artifacts are introduced into the system. Using high power toroidal transformers guarantees the exclusion of any high frequency noise through the power supply.

Technical Data

Technical Data

Digital displays: 3 1/2 digits, XX.X °C
Setpoint control: 3-turn potentiometer
range: 18°C to to 50.0 °C
Heater output: 12 V / 2 A, continuous DC
short circuit protected,
Control: PI (proportional-integral) controller,
factory-set parameters;
accuracy typically ±0.2 °C
Sensor input: for semiconductor 2252 Ohm at 25 °C,
accuracy typically 0.1 °C at 25 °C,
with electronic protection
Measuring accuracy: 0.1 °C at 25 °C
Power requirements: 115 V / 230 V AC, 60/50 Hz,
fuse 0.4 A / 0.2 A slow
Dimensions: desktop cabinet, 165 x 265 x 95 mm

Ordering

Ordering

Part no. Description
UNITEMP uniTemp Temperature Controller
UNITEMP-TS100 Temperature sensor for uniTemp systems

Downloads

Downloads

Manual uniTemp manual
Brochures uniTemp

Temperature Controllers